Disposable, Single use USB temperature data logger

The Single-use USB, PDF temperature data logger is for recording the temperature of medicines, vaccines, food, vegetables etc. This is a true plug and play device. It does not require any proprietary software for generating reports of recorded temperature data. This is a single-use disposable USB data logger also termed as a disposable data logger.

how-to-use-usb-disposable-temperature-data-logger

Features of economic single use USB temperature DataloggersUSB-temperature-data-logger

The main advantages of these disposable data loggers over reusable data loggers are as below.

  1. These single-use data loggers are economical, costing a fraction of the price of reusable data loggers.
  2. There are 5 LED alarm indicators on the disposable data logger. It will indicate whether the temperature has exceeded the higher or lower permitted levels. There are two levels of low alert levels (Blue LEDs) and two levels of bookmarks alerts (Red LEDs). Also, there is one Green LED to indicate that no alert was generated.
  3. It is very small in size and easy to attach to any part of a consignment, box etc.
  4. The customer can program the sampling interval between 5 seconds to 17 hours to suit the duration of the trip.
  5. We normally supply the USB data logger after programming all the parameters. However, the customer can easily reprogram the same any number of times until the first use.
  6. It does not require any particular software for downloading the recorded data. The receiver of the consignment may not have internet connections. Hence may not be able to download any special software. Our USB data logger requires only basic computer without any software including Microsoft office.Buy-online-single-use-USB-PDF-Data-Logger-VackerGlobal
  7. Even if there is no computer available at the receiving end, the status of recording can be seen on the LEDs on the single-use data logger.
  8. There are separate models available with display and without display. (The model with display requires free software for downloading the data)
  9. For each of them, there are two models available for the USB data logger. One with an inbuilt NIST traceable calibration certificate and the second model without a calibration certificate.
  10. The customer can use the same data logger for 15 days trip, 30-day trip, 45-day trip, 60-day trip, 90-day trip etc. Customer does not need to buy separate data logger for each purpose.  Either we will program the same to meet your trip duration or you can program yourself.
  11. These models comply with 21 CFR Part 11 standards.

VAC-V1 Disposable, Single-use, USB Temperature recorder with LED indicators (LCD display model available)

This single trip, USB data logger has the following features.

  1. The single-use data logger can record 13,000 readings of temperature alone.disposable-USB-logger-LED-alarm
  2. Based on your requirement you can program for a recording interval of one reading per second, one reading per minute, one reading per 5 minutes etc. up to one reading per day.
  3. The logger can operate, measure and record any temperature from -40 °C to +80 °C or -40°F to +176°F.
  4. It is designed in the USA.
  5. It is a highly accurate model with an error of maximum ±0.3°C from -40 °C to +80 °C.
  6. It has an internal sensor to measure the temperature accurately.
  7. You can make markings during the recordings which you can see in the report.
  8. The readings will be a resolution of 0.01°C, which means that the readings are like 10.02, 10.02 etc.
  9. It will have a maximum error of ±15 minutes per year.
  10. There are 5 LEDs and two buttons on the single-use data logger. One button is for Start and one button is for Stop
  11. Start and stop functions are either manual or through programming.
  12. Start and stop programming can be for a particular date and time.
  13. If you don’t want the recording function immediately upon starting, you can set a delay time. As an example, consider a case where you want to insert into a box of 4°C and the outside temperature is 24°C. If you start the recording manually outside the box, the current temperature will be 24°C. You may not want the first recording to be 24°C. Hence you can set a delay period of 10 minutes. As soon as you start the recording, you can insert into the box. The temperature sensor of the single-use data logger will come down and the first reading will be recorded only after 10 minutes.
  14. You can program 2 high alert levels and 2 low-level alerts. As an example consider medicines stored between 15°C o 25°C. You can set the first high alert at 25°C and the second alert at 30°C. Similarly, you can program the first low alert at 15°C and the second alert at 10°C.sample-pdf-report-single-use-data-logger
  15. From the above example, if the reading crosses 25°C, the first Red LED will start blinking. If the reading crosses 30°C, the second Red LED will start blinking. Similarly, Blue LEDs will start blinking for lower-level alerts. If the temperature was always within 15 to 25°C, the Green LED will be blinking indicating that the temperature has been always within the limits.
  16. Upon completion of recording, you can check the LEDs for the status. Then you can download the complete data with the graph in pdf, Excel or TXT formats. You can simply insert into any PC to generate the reports automatically. It supports all languages generally available on the computer.
  17. The programming of this disposable data logger is using our free software.
  18. If you want inbuilt calibration of the same models, please select our model VAC-V1P, which is pharma compliant model.
  19. The dimensions of the logger are 89mm x 49mm x 4.5 mm.
  20. It has an approximate weight of 10.8 grams.
  21. The battery lasts for 1 to 1.5 years but mainly depends on the operation conditions.
  22. We provide a warranty period of one year from the date of supply or up to the starting of the recording, whichever is earlier.

VAC-V1P Disposable, Single-use, USB Temperature Data Logger with LED indicators & Calibration report (LCD display model available)

This model of the single-use, disposable temperature data logger has a calibration report stored in the cloud storage. A link for opening the calibration report is available within the report of each data logger. All other technical details are as per the previous model VAC-V1.

VAC-V1LCD Disposable, Single-use, USB Temperature Data Logger with LCD Display

This single trip, USB data logger with LCD display has the following features.

  1. Buy-online-single-use-USB-PDF-Data-Logger-VackerGlobalThis single-use data logger has an LCD display screen with a size of 30 x 17mm.
  2. The single-use data logger can record 13,000 readings of temperature alone.
  3. Based on your requirement you can program for a recording interval of one reading per second, one reading per minute, one reading per 5 minutes etc. up to one reading per day.
  4. The logger can operate, measure and record any temperature from -40 °C to +80 °C or -40°F to +176°F.
  5. It is designed in the USA.
  6. It is a highly accurate model with an error of maximum ±0.3°C from -40 °C to +80 °C .
  7. IT has an internal sensor to measure the temperature accurately.
  8. You can make markings during the recordings which you can see in the report.
  9. The readings will be a resolution of 0.01°C, which means that the readings are like 10.02, 10.02 etc.
  10. t will have a maximum error of ±15 minutes per year.
  11. There are 5 LEDs and two buttons on the single-use data logger. One button is for Start and one button is for Stop
  12. Start and stop functions are either manually or through programming.
  13. Start and stop programming can be for a particular date and time.
  14. If you don’t want the recording function immediately upon starting, you can set a delay time. As an example, consider a case where you want to insert into a box of 4°C and the outside temperature is 24°C. If you start the recording manually outside the box, the current temperature will be 24°C. You may not want the first recording to be 24°C. Hence you can set a delay period of 10 minutes. As soon as you start the recording, you can insert into the box. The temperature sensor of the LED-alerts-of-USB-dataloggersingle-use data logger will come down and the first reading will be recorded only after 10 minutes.
  15. You can program 2 high alert levels and 2 low-level alerts. As an example consider medicines stored between 15°C o 25°C. You can set the first high alert at 25°C and the second alert at 30°C. Similarly, you can program the first low alert at 15°C and the second alert at 10°C.
  16. From the above example, if the reading crosses 25°C, the first Red LED will start blinking. If the reading crosses 30°C, the second Red LED will start blinking. Similarly, Blue LEDs will start blinking for lower-level alerts. If the temperature was always within 15 to 25°C, the Green LED will be blinking indicating that the temperature has been always within the limits.
  17. Upon completion of recording, you can check the LEDs for the status. Then you can download the complete data with the graph in pdf, Excel or TXT formats. You can simply insert into any PC to generate the reports automatically. It supports all languages generally available on the computer.
  18. The programming of this disposable data logger is using our free software.
  19. If you want inbuilt calibration of the same models, please select our model VAC-V1P, which is pharma compliant model.
  20. The dimensions of the logger are 104mm x 47mm x 7 mm.
  21. It has an approximate weight of 18 grams.
  22. The battery lasts for 1 to 1.5 years but mainly depends on the operation conditions.
  23. We provide a warranty period of one year from the date of supply or up to the starting of the recording, whichever is earlier.

VAC-V1LCD-P Disposable, Single-use, USB Temperature Data Logger with LCD Display & Calibration report

This model of the single-use, disposable temperature data logger with LCD display has a calibration report stored in the cloud storage. A link for opening the calibration report is available within the report of each data logger. All other technical details are as per the model VAC-V1LCD.

VAC-MS-ST-S-8, USB, Disposable temperature data Logger

The technical details of this data logger are given below:

  1. The product code of USB data logger without inbuilt calibration report is USB temperature data logger VAC-MS-ST-S-8.
  2. The product code of USB data logger with inbuilt calibration report is USB temperature data logger VAC-MS-ST-S-8 (Pharma Compliant with inbuilt NIST traceable calibration certificate).
  3. The product type is USB type is disposable data logger also known as a single-use data logger.
  4. Measuring parameter is Temperature only.
  5. Memory capacity is 7928 readings. This means if we record the readings every 5minutes, it will last for 27 days. If we record the reading every 3 minutes, it will last 16 days. While programming you can change the interval and see how long it will last.
  6. The interval between readings is programmable from 5 seconds to 17 hours. This interval determines the total duration of recording as per description in the above column under ‘Memory capacity’. Typically, for medicines customer chose a sampling interval of 3 to 5 minutes. For food and vegetables, you may prefer a sampling interval of 10 to 30 minutes. This is entirely up to the manufacturer and the transporter depending on the type and sensitivity of the goods. Also, you will have to consider the total duration of transportation to decide the sampling interval.
  7. For using as a 30 days data logger, we can program a recording interval of 6 minutes. You can use the same as 10 days of the data logger and 20 days of the data logger. For using as a 60 days data logger, we will program with 11-minute recording interval (You can also easily reprogram any number of times)
  8. Type of sensor is internal on the side of the single-use data logger.
  9. Measuring Temperature Range is form -40 ⁰C to +80 ⁰C (-40 ⁰F to +176 ⁰F).
  10. Temperature Accuracy Between -40 ⁰C to -10 ⁰C (-40 ⁰F to +14 ⁰F) is ±0.5 ⁰C / ±1 ⁰F
  11. Temperature Accuracy Between -10 ⁰C to +80 ⁰C (+14 ⁰F to +176 ⁰F) is ±0.3 ⁰C / ±0.6 ⁰F
  12. Resolution of reading is 0.1⁰C (0.1 ⁰F). Resolution means the difference between each reading. This will be 0.1, eg. 2.1, 2.2,2.3 etc.
  13. Alarm indications are available at 4 thresholds viz. 2 red LEDs, 2 blue LEDs.
  14. Available alarm Configurations are High-high, high, low & low-low.
  15. We supply the same in a programmed condition. The customer can reprogram all parameters any number of times until first use.Buy-online-single-use-USB-PDF-Data-Logger-VackerGlobal
  16. The customer can program start delay so that the recording will commence after a certain duration after pressing the start button. The delay can be from 1 minute to 99 days.
  17. The size of the data logger is 68x37x5mm (without sleeve). With the sleeve, the size is 81x52x5mm.
  18. Battery life is up to 1 year depending upon storage conditions.
  19. Reports are generated in PDF, TXT, CSV & CVT formats (For opening a CVT file, you need our free Console plus software)
  20. Ingress Protection (IP rating) is IP 65. This means Extreme protection against water and solid particles.
  21. Software for programming is our free Console plus software ( Please see our video on how to install the software)
  22. 3 point NIST traceable calibration is part of the PDF report in the Pharma compliant models. The normal model comes with a factory test report with serial numbers.
  23. A bookmarking facility is available for up to 8 bookmarks. After commencing the recording, the customer can use this feature to note any events (eg. stopping a vehicle at a certain point). In order to do this, simply press the start button for a few seconds. In the report, the bookmarks will be indicated.

VAC-MS-ST-S-8-P, USB, Disposable temperature data Logger, Pharma compliant with an inbuilt calibration reportsingle-use-temperature-data-logger-cryopak

This model of the single-use, disposable temperature data logger has an inbuilt calibration report. You can see the calibration report in the report. All other technical details are same as VAC-MS-ST-S-8.

Simple operational methods of data logger:

The operation of the disposable data logger is extremely simple. We generally supply the USB data logger after programming.

The usage instructions are:

  1. If the disposable data logger is already programmed and ready to start, the green LED will blink lightly at approximately every 8 seconds.
  2. In order to start the recording, press the ‘Start’ button for 3-4seconds. All the LED indicators will blink in a row starting from Blue LED and ending with Red LED. This indicates that the logger started recording.
  3. Once the recording starts, the green LED will blink brightly twice every 4 seconds.
  4. If an alarm event occurs, the corresponding Red or Blue LED will blink twice every 4 seconds.
  5. In order to stop recording, simply press the ‘Stop’ button for 3-5 seconds and all LEDs will blink in a row from Red to Blue (This is the opposite direction to that of starting).
  6. The recording stops either when pressing the ‘Stop’ button or when the customer inserts the same into a PC. Thereafter you cannot use it for recording any further readings.

Alert indicators on USB temperature data logger

disposable-USB-data-logger-LED-alarm

Alarms of USB disposable data logger

There are 5 LED indicators on the USB data logger. These LEDs will indicate whether the temperature has always been within the permitted range.

Eg. if the desired temperature of storage is 2-8 Degree Centigrade, we can program the alerts as under:

 

  1. Second high alert (termed as HIghHigh alert): 12 Deg C
  2. First High Alert (termed as High Alert): 8 Deg C
  3. First Low alert : (termed as Low alert): 2 Deg C
  4. Second Low Alert (termed as LowLow alert) : 0 Deg C

During the recording, if the temperature goes below 2 Degree, but not zero degrees, it activates the first low alert. This is the first blue LED known as Low and it will start blinking.

During the recording, if the temperature reaches 12 Degree, it activates the first and second high alert. Hence both red LEDs will be blinking (High and High High).

sample-pdf-report-single-use-data-logger

Sample pdf report of disposable USB data logger

If the recording was always between 2 and 8 Degree C, the green LED only will be blinking.

Also, we can program the delay before generating an alarm. The following type of delays can be programmed.

Consecutive delay before alarm-There are options between 1 and 254. A consecutive delay of 5 means that if 5 consecutive readings are out of the range, it activates the corresponding LED.

Total delay before alarm-This can be programmed between 1 and 254. As an example consider that the total delay of 5 is programmed. This means that if 5 readings (consecutive or otherwise) are out of the range, it activates the corresponding LED.

Generating reports on a USB data logger (Plug and play operation)

This disposable data logger is a plug and play device. It does not need any software for downloading the reports. It generates reports in CSV, pdf, Text & CVT formats. For opening the CVT format you need our free console plus software. This will not be of general use for a customer.

Buy-online-single-use-USB-PDF-Data-Logger-VackerGlobal

If Microsoft office® package is installed, the customer can view the CSV file in MS Excel. If the computer has a pdf reader, it can read the pdf report. If MS Office® or pdf reader is not available, the customer can read the text file using the program ‘notepad’. This is part of the standard MS Windows® installation.sample-csv-report-usb-data-logger

There is a protective transparent plastic sleeve around the single-use data logger for protecting the device from moisture and water.

Automatically generated Sample reports

Please view the sample reports automatically generated by the USB data temperature logger:

Sample Pdf report
Sample CSV report
Sample text report

Price of USB Disposable data logger

Indicative price of single-use USB Temperature data loggers in UAE is indicated. These prices are for reference only and may vary depending on the quantity and place of delivery:

Price of data logger type MS-ST-S-8 :

inbuilt-calibration-certificate-disposable-USB-data-logger

Inbuilt calibration certificate of disposable temperature data logger in compliance with 21CFRPart11.

The unit price will be USD 25.00 each, subject to Taxes & duties applicable in your country. This price is for the purchase of a single piece. Please contact us indicating the required quantity.

Please check the latest prices and buy these data loggers from Vacker online store. 

Please click to download the catalogue of this product

Price of data logger type MS-ST-S-8-P :

This is the Pharma compliant model with inbuilt NITS traceable calibration certificate.

The unit price for this model including all taxes and delivery charges will be USD 30.00 Each subject to Taxes and duties applicable in your country. This price is for the purchase of a single piece. Please contact us indicating the required quantity.

Please check the latest prices and buy these data loggers from Vacker online store.

Video of iMini pdf logger

Programming of USB Temperature data logger

By default we program the following values on the USB temperature data logger (unless otherwise specified by the customer):

    1. Recording interval will be 5 minutes (This will last for 27 days of recording).
    2. LED alert indications:programming-details-for-usb-temperature-data-logger

The alert indications will be set to ‘ON’ at the following values:

HH alarm: 30 °C

H alarm: 25°C

L Alarm: 15°C

LL alarm: 10°C

  1. Start delay is 5 minutes
  2. Stop button is enabled

Also please see our separate page for demonstration and operational instructions.
For ordering a USB data logger, you may take a print out of the sheet onto the right side and fill up necessary details based on which we will program the same for you.

Single-use data logger with LCD Display

single-use-data-logger-with-LCD-display

Single-use data logger with LCD display

This is the latest single-use data logger by Cryopak, USA which has an LCD display displaying current readings and status. The operational details are similar to the previous disposable data logger without display. However, this disposable data logger requires console plus software to download the data. All programming instructions and type of reports also are similar to other types of single-use data logger.

You can also buy these data loggers from Vacker online store.

Please click to download the catalogue of this product

Product Description of Single-use temperature recorder

  1. Brief Title of the device: Single-use, Disposable USB type temperature recorder.
  2. Brief Description of the device: USB type temperature recorders. (Buy online at our store.) Disposable type for one-time use only. LED indicators to indicate whether the temperature has gone above or below the permitted levels. It can generate pdf and CSV (opens in Excel) reports without any software related to the data recorder. We can program the programming intervals and alert levels. Customer can also program themselves.
  3. Model number: VAC-MS-ST-S-8
  4. Brand: VackerGlobal
  5. Seller: VackerGlobal
  6. SKU Number: 1000000004
  7. Price (USD): 26.00
  8. Price Validity: 31 December 2020

Buy-online-single-use-USB-PDF-Data-Logger-VackerGlobal

FAQ of Single-use temperature recording USB loggers

  1. What is a single-use temperature recorder or temperature data logger?
    This is a temperature recorder to record the temperature of medicines, vaccines, food items, fruits vegetables etc. It can record only one time until the memory is full. You can dispose of this recorder after completing the recording.
  2. What is the use of a single-use temperature recorder?
    The main application is during transportation of medicines, vaccines, food items, frozen food, fruits vegetables etc. This is to record the temperature during the transportation period. The consignee can check the recording before accepting the goods.
  3. How to decide whether I should use a single-use or multi-use temperature recorder?
    If you are despatching some items to another state or country, it is ideal to use this disposable logger. If you are using a multiple-use recorder, you may want to collect it after use, since it is costly.
  4. What are the advantages of a single-use temperature recorder?
    These are economical, simple to use devices. These are programmable to suit your needs. You can check the status of the temperature without downloading the data.
  5. What are the disadvantages of a single-use temperature recorder?
    Once the battery is over, you cannot download the data. Hence as soon as you receive the data logger, you have to download the data and keep the reports in a PC. Normally the battery lasts 1 to 2 years based on temperature conditions.
  6. How to use a single-use temperature recorder? Most of the suppliers supply these recorders after programming. Hence you don’t have to worry about programming. Simply press the start button to commence the recording. Upon receipt of the goods at the destination, simply insert into a PC to download the data.

We supply these single-use, disposable data loggers in the United States of America, United Kingdom, Germany, France, Netherlands and all other European countries.

Also, we supply these single-use, disposable data loggers in Asian countries covering India, Pakistan, Hong Kong, Singapore, Srilanka, Bangladesh, Kuwait, Oman, Qatar, United Arab Emirates, Kingdom of Saudi Arabia, Bahrain, Iraq, Afghanistan, Kazakhstan etc. Our Dubai office caters entire Middle East countries including Lebanon, Egypt, Jordan, Libya, Tunisia etc.
In Africa, we supply these single-use, disposable data loggers to all countries including South Africa, Ghana, Angola, Kenya, Algeria, Tanzania, Djibouti, Chad, Rwanda, Uganda, Nigeria, Ethiopia, Morocco, etc.